Search results for "Thermoluminescence dosimetry"

showing 2 items of 2 documents

Seasonal variation of air kerma rate in Sicily.

2007

Thermoluminescence dosimetry has been used to measure air kerma in 29 sites in Sicily. Four three month measurement campaigns have been carried out in order to assess seasonal variations. Average annual values between 20 and 90 nGy h(-1), after cosmic background subtraction, are reported. Average annual values are strongly dependent on site lithology, and we find that winter data are generally the highest, while spring and autumn rates are generally the lowest with very similar trends in any site. Summer values generally lay in between. Largest seasonal variations are found in sites along the southern coast of the island, probably because of stronger action of winds affecting radon, along w…

LithologyHealth Toxicology and MutagenesisAir pollutionchemistry.chemical_elementRadonmedicine.disease_causeAtmospheric sciencesKermaRadiation MonitoringmedicineEnvironmental ChemistryWaste Management and DisposalSicilyGeographybusiness.industryGeneral MedicineSeasonalitymedicine.diseasePollutionGround levelSpectrometry GammachemistryAir Pollutants RadioactiveThermoluminescence dosimetrySpatial variabilitySeasonsNuclear medicinebusinessJournal of environmental radioactivity
researchProduct

A practical and transferable methodology for dose estimation in irradiated spices, based on thermoluminescence dosimetry

2008

Abstract The thermoluminescence technique is recommended by the European Committee for Standardization for the detection of irradiated food containing silicates as contaminants. In this work, the applicability of the thermoluminescence technique as a quantitative method to assess the original dose in irradiated oregano was studied; the additive-dose method was used, with reirradiation doses up to 600 Gy. The proposed new procedure allows to clearly discriminate irradiated from unirradiated samples, even after one year storage, and it gives an acceptable estimation of the original dose; the overall modified procedure requires only one day to be completed.

RadiationMaterials scienceThermoluminescence irradiated fooddosimetryfood irradiationRadiochemistryReproducibility of ResultsRadiation DosageSensitivity and SpecificityThermoluminescenceSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Dose estimationThermoluminescent Dosimetrythermoluminescence irradied spicesDosimetryThermoluminescent DosimetryRadurizationFood irradiationThermoluminescence dosimetryIrradiationSpicesFood Contamination RadioactiveFood Analysisthermoluminescence
researchProduct